N. Cho, J. Yoo, S. Song, J. Lee, S. Jeon et al., The human body characteristics as a signal transmission medium for intrabody communication, IEEE Transactions on Microwave Theory and Techniques, vol.55, pp.1080-1086, 2007.

P. Dario, C. Stefanini, and A. Menciassi, Modeling and experiments on a legged microrobot locomoting in a tubular, compliant and slippery environment, The 9th International Symposium on Experimental Robotics-ISER, 2004.

A. Flynn, K. Udayakumar, D. Barret, J. Mclurkin, D. Franck et al., Tomorrow's surgery: micromotors and microrobots for minimally invasive procedures, Journal of Minimally Invasive Therapy and Allied Technologies, vol.7, issue.4, pp.343-352, 1998.

A. Fritscher-ravens, C. A. Mosse, and D. Mukherjee, Transgastric gastropexy and hiatal hernia repair for gerd under eus control: a porcine model, Gastrointest Endosc, vol.59, pp.89-95, 2004.

B. Hannaford, A design framework for teleoperators with kinesthetic feedback, IEEE Trans. Rubotics Automat, vol.5, issue.4, pp.426-434, 1989.

J. P. Hespanha and A. S. Morse, Switching between stabilizing controllers, Automatica, vol.38, issue.11, pp.1905-1917, 2002.

P. F. Hokayem and M. W. Spong, Bilateral teleoperation: an historical survey, Automatica, vol.42, pp.2035-2057, 2006.

S. B. Jagannath, S. V. Kantsevoy, and C. A. Vaughn, Peroral transgastric endoscopic ligation of fallopian tubes with long-term survival in a porcine model, Gastrointest Endosc, vol.61, pp.449-453, 2005.

W. H. Edwin and . Jager, Microfabricating conjugated polymer actuators, Elisabeth Smela, and Olle Ingan?s, vol.290, pp.1540-1545, 2000.

K. Sumiyam, C. J. Gostout, and E. Rajan, Transgastric cholecystectomy: transgastric accessibility to the gallblader improved with the semf method and a novel multibending therapeutic endoscope, Gastrointestinal endoscopy, vol.65, pp.1028-1034, 2007.

A. Karalis, J. D. Joannopoulos, and M. Soljacic, Efficient wireless non-radiative mid-range energy transfer, Annals of Physics, vol.323, pp.34-48, 2008.

H. Kazerooni, T. I. Tsay, and C. L. Moore, Telefunctioning: an approach to telerobotic manipulations, Proc. Amer. Contr. Conf, pp.2778-2783, 1990.

K. Y. Kim, Y. Sun, R. M. Voyles, and B. J. Nelson, Calibration of multiaxis mems force sensors using the shape from motion method, IEEE Sensors Journal, vol.7, issue.3, pp.344-351, 2007.

D. A. Lawrence, Stability and transparency in bilateral teleoperation, IEEE transactions on Robotics and Automation, vol.9, issue.5, pp.624-637, 1993.

A. Lehman, K. Berg, J. Dumpert, N. A. Wood, A. Q. Visty et al., Surgery with cooperative robots, vol.13, issue.2, pp.95-105, 2008.

A. Lehman, N. A. Wood, J. Dumpert, D. Oleynikov, and S. M. Farritor, Robotic natural orifice transluminal endoscopic surgery, Proc. of the 2008 IEEE International Conference on Robotics and Automation, pp.2969-2974, 2008.

L. G. Machado and M. A. Savi, Medical application of shape memory alloys, Brazilian Journal of Medical and Biological Research, vol.36, issue.6, pp.683-691, 2003.

A. Menciassi, A. Moglia, S. Gorini, G. Pernorio, C. Stefanini et al., Shape memory alloy clamping devices of a capsule for monitoring tasks in the gastrointestinal tract, Journal of Micromechanics and Microengineering, vol.15, issue.11, pp.2045-2055, 2005.

H. Ono, H. Kondo, and T. Gotoda, Endoscopic mucosal resection for treatment of early gastric cancer, Gut, vol.48, pp.225-229, 2001.

P. O. Park, M. Bergstrom, K. Ikeda, A. Fritscher-ravens, and P. Swain, Experimental studies of transgastric gallbladder surgery: cholecystectomy and cholecystogastric anastomosis (videos), Gastrointest Endosc, vol.61, pp.601-606, 2005.

M. Pasricha, R. A. Kozarek, and P. Swain, A next generation therapeutic endoscope: development of a novel endoluminal surgery system with "birds-eye" visualization and triangulating instruments, Gastroenterology, 2009.

J. Peirs, J. Clijnen, P. Herijgers, D. Reynaerts, H. Van-brussel et al., A micro optical force sensor for force feedback during minimally invasive robotic surgery, Proc. of the 17th European Conference on Solid-State Transducers, vol.115, pp.447-455, 2004.

M. Rentschler, J. Dumpert, S. R. Platt, S. Farritor, and D. Oleynikov, Mobile in vivo robots provide sole visual feedback for abdominal exploration and cholecystectomy, Surgical Endoscopy, vol.20, pp.135-138, 2006.

M. Rentschler, J. Dumpert, S. R. Platt, S. Farritor, and D. Oleynikov, Natural orifice surgery with an endoluminal mobile robot, Surgical Endoscopy, vol.21, pp.1212-1215, 2007.

W. O. Richards, H. L. Houston, A. Torquati, L. Khaitan, M. D. Holzman et al., Paradigm shift in the management of gastroesophageal reflux disease, Ann Surg, vol.237, pp.638-647, 2003.

S. Seewald, S. Groth, and S. Omar, Aggressive endoscopic therapy for pancreatic necrosis and pancreatic abscess: a new safe and effective treatment algorithm (videos), Gastrointest Endosc, vol.62, pp.92-100, 2005.

M. Shahinpoor, Potential applications of electroactive polymer sensors and actuators in mems technologies, Proc. of the SPIE : Smart Materials, vol.4234, pp.203-214, 2001.

V. K. Sharma, M. Moirano, G. Depetris, and D. E. Fleischer, Successful ablation of barrett's esophagus with low-grade dysplasia (lgd) using barrx balloon device, Presented at: Digestive Disease Week, pp.1881-1886, 2005.

Y. Shen, C. A. Ning-xi, U. C. Pomeroy, W. J. Wejinya, and . Li, An active micro-force sensing system with piezoelectric servomechanism, Proc. of the IEEE/RSJ International Conference on Intelligent Robots and Systems, pp.2381-2386, 2005.

D. Stoyanov, G. P. Mylonas, and G. Yang, Gazecontingent 3d control for focused energy ablation in robotic assisted surgery, MICCAI '08: Proceedings of the 11th International Conference on Medical Image Computing and Computer-Assisted Intervention, vol.2, pp.347-355, 2008.

M. Sultan and R. A. Norton, Esophageal diameter and the treatment of achalasia, The American Journal of Digestive Diseases and Sciences, vol.14, issue.9, pp.611-618, 1969.

Y. Sun, D. P. Potasek, D. Piyabongkarn, R. Rajamani, and B. J. Nelson, Actively servoed multi-axis microforce sensors, Proc. of the IEEE International Conference on Robotics and Automation, pp.294-299, 2003.

F. Tendick, S. Shankar, R. S. Sastry, M. Fearing, and . Cohn, Applications of micromechatronics in minimally invasive surgery : Focused section on micromechatronics, IEEE/ASME transactions on mechatronics, vol.2, issue.1, pp.34-42, 1998.

M. Marc-simon-wegmueller, N. Oberle, N. Felber, W. Kuster, and . Fichtner, Digital data communication through the human body for biomedical monitoring sensor, World Congress on Medical Physics and Biomedical Engineering, vol.14, issue.7, pp.608-612, 2006.

W. Zarrad, P. Poignet, R. Cortesao, and O. Company, Stability and transparency analysis of a haptic feedback controller for medical applications, Proc. IEEE Conf. on Decision and Control, pp.5767-5772, 2007.
URL : https://hal.archives-ouvertes.fr/lirmm-00202630

W. Zarrad, P. Poignet, R. Cortesao, and O. Company, Towards teleoperated needle insertion with haptic feedback controller, IEEE/RSJ International Conference on Intelligent Robots and Systems, pp.1254-1259, 2007.
URL : https://hal.archives-ouvertes.fr/lirmm-00186804