A. Ajoudani and A. Erfanian, A Neuro-Sliding-Mode Control With Adaptive Modeling of Uncertainty for Control of Movement in Paralyzed Limbs Using Functional Electrical Stimulation, IEEE Transactions on Biomedical Engineering, vol.56, issue.7, pp.1771-1780, 2009.
DOI : 10.1109/TBME.2009.2017030

A. Coste, C. Jovic, J. Pissard-gibollet, R. Froger, and J. , Continuous gait cycle index estimation for electrical stimulation assisted foot drop correction, Journal of NeuroEngineering and Rehabilitation, vol.11, issue.1, pp.118-128, 2014.
DOI : 10.1016/j.robot.2007.09.019

URL : https://hal.archives-ouvertes.fr/hal-01060086

S. Binder-macleod and L. Snyder-mackler, Muscle Fatigue: Clinical Implications for Fatigue Assessment and Neuromuscular Electrical Stimulation, Physical Therapy, vol.73, issue.12, pp.902-910, 1993.
DOI : 10.1093/ptj/73.12.902

T. M. Bruns, J. B. Wagenaar, M. J. Bauman, R. A. Gaunt, W. et al., Real-time control of hind limb functional electrical stimulation using feedback from dorsal root ganglia recordings, Journal of Neural Engineering, vol.10, issue.2, pp.26020-26030, 2013.
DOI : 10.1088/1741-2560/10/2/026020

Z. J. Cai, E. Bai, and R. K. Shields, Fatigue and non-fatigue mathematical muscle models during functional electrical stimulation of paralyzed muscle, Biomedical Signal Processing and Control, vol.5, issue.2, pp.87-93, 2010.
DOI : 10.1016/j.bspc.2009.12.001

M. K. Chan, R. K. Tong, C. , K. Y. , and -. , Bilateral Upper Limb Training With Functional Electric Stimulation in Patients With Chronic Stroke, Neurorehabilitation and Neural Repair, vol.23, issue.4, pp.357-365, 1177.
DOI : 10.1177/1545968308326428

J. J. Chen, Y. , and N. Y. , The validity of stimulus-evoked EMG for studying muscle fatigue characteristics of paraplegic subjects during dynamic cycling movement, IEEE Transactions on Rehabilitation Engineering, vol.5, issue.2, pp.170-178, 1997.
DOI : 10.1109/86.593288

N. C. Chesler and W. K. Durfee, Surface EMG as a fatigue indicator during FES-induced isometric muscle contractions, Journal of Electromyography and Kinesiology, vol.7, issue.1, pp.27-37, 1997.
DOI : 10.1016/S1050-6411(96)00016-8

C. J. Deluca and Z. Erim, Common drive of motor units in regulation of muscle force, Trends in Neurosciences, vol.17, issue.7, pp.299-305, 1994.
DOI : 10.1016/0166-2236(94)90064-7

N. D. Donaldson, T. A. Perkins, and A. C. Worley, Lumbar Root Stimulation for Restoring Leg Function: Stimulator and Measurement of Muscle Actions, Artificial Organs, vol.23, issue.6, 1997.
DOI : 10.1111/j.1525-1594.1997.tb04660.x

W. K. Durfee, Chapter 33 Control of standing and gait using electrical stimulation: influence of muscle model complexity on control strategy, Prog. Brain Res, vol.97, issue.08, pp.369-381, 1993.
DOI : 10.1016/S0079-6123(08)62296-7

A. Dutta, R. Kobetic, and R. J. Triolo, Ambulation After Incomplete Spinal Cord Injury With EMG-Triggered Functional Electrical Stimulation, IEEE Transactions on Biomedical Engineering, vol.55, issue.2, pp.791-794, 2007.
DOI : 10.1109/TBME.2007.902225

URL : https://hal.archives-ouvertes.fr/hal-01062440

R. H. Edwards, Human Muscle Function and Fatigue, Ciba Found. Symp, vol.57, pp.1-18, 1981.
DOI : 10.1002/9780470715420.ch1

A. Erfanian, H. J. Chizeck, and R. M. Hashemi, Excitation-contraction fatigue during sustained electrical stimulation of paralyzed muscle, Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, pp.1460-1461, 1996.
DOI : 10.1109/IEMBS.1996.647504

A. Erfanian, H. J. Chizeck, and R. M. Hashemi, Using evoked EMG as a synthetic force sensor of isometric electrically stimulated muscle, IEEE Transactions on Biomedical Engineering, vol.45, issue.2, pp.188-202, 1998.
DOI : 10.1109/10.661267

M. Ferrarin, F. Palazzo, R. Riener, and J. And-quintern, Model-based control of FES-induced single joint movements, IEEE Transactions on Neural Systems and Rehabilitation Engineering, vol.9, issue.3, pp.245-257, 2001.
DOI : 10.1109/7333.948452

C. Freeman, Newton-method based iterative learning control for robot-assisted rehabilitation using FES, Mechatronics, vol.24, issue.8, pp.934-943, 2014.
DOI : 10.1016/j.mechatronics.2014.04.001

S. Gandevia, R. M. Enoka, A. J. Mccomas, D. G. Stuart, T. et al., Fatigue: Neural and Muscular Mechanisms, 1995.
DOI : 10.1007/978-1-4899-1016-5

T. Hamada, T. Kimura, and T. Moritani, Selective fatigue of fast motor units after electrically elicited muscle contractions, Journal of Electromyography and Kinesiology, vol.14, issue.5, pp.531-538, 2004.
DOI : 10.1016/j.jelekin.2004.03.008

M. Hayashibe, D. Guiraud, J. L. Pons, and D. Farina, Editorial: Biosignal processing and computational methods to enhance sensory motor neuroprosthetics, Frontiers in Neuroscience, vol.8, issue.181, 2015.
DOI : 10.3389/fnins.2014.00181

URL : https://hal.archives-ouvertes.fr/lirmm-01235841

M. Hayashibe, Q. Zhang, and C. Azevedo-coste, Dual predictive control of electrically stimulated muscle using biofeedback for drop foot correcti, Proceeding in IEEE/RSJ International Conference on Intelligent Robots and Systems, pp.1731-1736, 2011.

M. Hayashibe, Q. Zhang, D. Guiraud, and C. Fattal, Evoked EMG-based torque prediction under muscle fatigue in implanted neural stimulation, Journal of Neural Engineering, vol.8, issue.6, pp.6-10, 2011.
DOI : 10.1088/1741-2560/8/6/064001

URL : https://hal.archives-ouvertes.fr/lirmm-00630237

J. M. Heasman, T. R. Scott, V. A. Vare, R. Y. Flynn, C. R. Gschwind et al., Detection of fatigue in the isometric electrical activation of paralyzed hand muscles of persons with tetraplegia, IEEE Transactions on Rehabilitation Engineering, vol.8, issue.3, 2000.
DOI : 10.1109/86.867870

S. Jezernik, G. V. Wassink, and T. Keller, Sliding Mode Closed-Loop Control of FES: Controlling the Shank Movement, IEEE Transactions on Biomedical Engineering, vol.51, issue.2, pp.263-272, 2003.
DOI : 10.1109/TBME.2003.820393

T. E. Johnston, R. R. Betz, B. T. Smith, and M. J. Mulcahey, Implanted functional electrical stimulation: an alternative for standing and walking in pediatric spinal cord injury, Spinal Cord, vol.41, issue.3, pp.144-152, 2003.
DOI : 10.1038/sj.sc.3101392

T. Keller and A. Kuhn, Electrodes for transcutaneous (surface) electrical stimulation, Journal of Automatic Control, vol.18, issue.2, pp.35-45, 2008.
DOI : 10.2298/JAC0802035K

URL : http://doi.org/10.2298/jac0802035k

R. Kobetic, R. J. Triolo, and E. B. Marsolais, Muscle selection and walking performance of multichannel FES systems for ambulation in paraplegia, IEEE Transactions on Rehabilitation Engineering, vol.5, issue.1, pp.23-29, 1997.
DOI : 10.1109/86.559346

O. Levin and J. Mizrahi, EMG and metabolite-based prediction of force in paralyzed quadriceps muscle under interrupted stimulation, IEEE Transactions on Rehabilitation Engineering, vol.7, issue.3, pp.301-314, 1999.
DOI : 10.1109/86.788467

Z. Li, D. Guiraud, D. Andreu, M. Benoussaad, C. Fattal et al., Real-time estimation of FES-induced joint torque with evoked EMGapplication to spinal cord injured patients, J. Neuroeng. Rehabil, 2016.

Z. Li, M. Hayashibe, D. Andreu, and D. Guiraud, A system for realtime estimation of joint torque with evoked EMG under electrical stimulation, Replace, Repair, Restore, Relieve Bridging Clinical and Engineering Solutions in Neurorehabilitation SE -76, 2014.
URL : https://hal.archives-ouvertes.fr/lirmm-00983717

Z. Li, M. Hayashibe, D. Andreu, and D. Guiraud, Real-time closedloop FES control of muscle activation with evoked EMG feedback, 7th International IEEE/EMBS Conference on Neural Engineering (NER), pp.2015-623, 2015.
URL : https://hal.archives-ouvertes.fr/lirmm-01235859

Z. Li, M. Hayashibe, C. Fattal, and D. Guiraud, Muscle Fatigue Tracking with Evoked EMG via Recurrent Neural Network: Toward Personalized Neuroprosthetics, IEEE Computational Intelligence Magazine, vol.9, issue.2, pp.38-46, 2014.
DOI : 10.1109/MCI.2014.2307224

URL : https://hal.archives-ouvertes.fr/lirmm-00980641

W. Liberson, H. Holmquest, and M. Scott, FUNCTIONAL ELECTROTHERAPY, ASAIO Journal, vol.8, issue.1, pp.202-205, 1961.
DOI : 10.1097/00002480-196204000-00075

N. A. Maffiuletti, M. A. Minetto, D. Farina, and R. Bottinelli, Electrical stimulation for neuromuscular testing and training: state-of-the art and unresolved issues, European Journal of Applied Physiology, vol.28, issue.10, pp.2391-2397, 2011.
DOI : 10.1007/s00421-011-2133-7

S. Mangold, T. Keller, A. Curt, and V. Dietz, Transcutaneous functional electrical stimulation for grasping in subjects with cervical spinal cord injury, Spinal Cord, vol.43, issue.1, 2005.
DOI : 10.1038/sj.sc.3101644

R. Merletti, M. Knaflitz, and C. J. Deluca, Electrically evoked myoelectric signals, Crit. Rev. Biomed. Eng, vol.19, pp.293-340, 1992.
DOI : 10.1109/iembs.1992.5761830

J. Mizrahi, M. Levy, H. Ring, E. Isakov, and A. Liberson, EMG as an indicator of fatigue in isometrically FES-activated paralyzed muscles, IEEE Transactions on Rehabilitation Engineering, vol.2, issue.2, pp.57-65, 1994.
DOI : 10.1109/86.313147

J. Mizrahi, D. Seelenfreund, E. Isakov, and Z. Susak, Predicted and Measured Muscle Forces after Recoveries of Differing Durations Following Fatigue in Functional Electrical Stimulation, Artificial Organs, vol.333, issue.3, pp.236-239, 1997.
DOI : 10.1111/j.1525-1594.1997.tb04657.x

R. North, Neural Interface Devices: Spinal Cord Stimulation Technology, Proc. IEEE 96, pp.1108-1119, 2008.
DOI : 10.1109/JPROC.2008.922558

D. T. Keeffe, A. E. Donnelly, and G. M. Lyons, The development of a potential optimized stimulation intensity envelope for drop foot applications, IEEE Transactions on Neural Systems and Rehabilitation Engineering, vol.11, issue.3, pp.249-256817678, 2003.
DOI : 10.1109/TNSRE.2003.817678

C. Pelletier and A. L. Hicks, Muscle fatigue characteristics in paralyzed muscle after spinal cord injury, Spinal Cord, vol.87, issue.1, 2011.
DOI : 10.1007/BF00417776

R. Riener, Model-based development of neuroprosthesis for paraplegic patients, Philos. Trans. R. Soc. Lond. Series B Biol. Sci, vol.354, pp.877-894, 1999.

R. Riener, J. Quintern, and G. Schmidt, Biomechanical model of the human knee evaluated by neuromuscular stimulation, Journal of Biomechanics, vol.29, issue.9, pp.1157-1167, 1996.
DOI : 10.1016/0021-9290(96)00012-7

M. Toussaint, D. Andreu, P. Fraisse, and D. Guiraud, Wireless Distributed Architecture for Therapeutic Functional Electrical Stimulation: a technology to design network-based muscle control, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology, pp.6218-6221, 2010.
DOI : 10.1109/IEMBS.2010.5627724

URL : https://hal.archives-ouvertes.fr/lirmm-00506293

R. Triolo, C. Bieri, J. Uhlir, R. Kobetic, A. Scheiner et al., Implanted functional neuromuscular stimulation systems for individuals with cervical spinal cord injuries: Clinical case reports, Archives of Physical Medicine and Rehabilitation, vol.77, issue.11, pp.1119-1128, 1996.
DOI : 10.1016/S0003-9993(96)90133-1

T. Watanabe and K. Fukushima, An Approach to Applying Feedback Error Learning for Functional Electrical Stimulation Controller: Computer Simulation Tests of Wrist Joint Control, Advances in Artificial Neural Systems, vol.32, issue.10, pp.1-8, 2010.
DOI : 10.1016/0021-9290(96)00026-7

Q. Zhang, M. Hayashibe, and C. Azevedo-coste, Evoked Electromyography-Based Closed-Loop Torque Control in Functional Electrical Stimulation, IEEE Transactions on Biomedical Engineering, vol.60, issue.8, pp.2299-2307, 2013.
DOI : 10.1109/TBME.2013.2253777

URL : https://hal.archives-ouvertes.fr/lirmm-00806283

Q. Zhang, M. Hayashibe, P. Fraisse, and D. Guiraud, FES-Induced Torque Prediction With Evoked EMG Sensing for Muscle Fatigue Tracking, IEEE/ASME Transactions on Mechatronics, vol.16, issue.5, pp.816-826, 2011.
DOI : 10.1109/TMECH.2011.2160809

URL : https://hal.archives-ouvertes.fr/lirmm-00604670

Q. Zhang, M. Hayashibe, and D. Guiraud, Muscle fatigue tracking based on stimulus evoked EMG and adaptive torque prediction, 2011 IEEE International Conference on Robotics and Automation, pp.1433-1438, 2011.
DOI : 10.1109/ICRA.2011.5980087

URL : https://hal.archives-ouvertes.fr/lirmm-00588948

A. Ziai and C. Menon, Comparison of regression models for estimation of isometric wrist joint torques using surface electromyography, Journal of NeuroEngineering and Rehabilitation, vol.8, issue.1, pp.56-66, 2011.
DOI : 10.1109/TRA.2003.808873