A Neuro-Sliding-Mode Control With Adaptive Modeling of Uncertainty for Control of Movement in Paralyzed Limbs Using Functional Electrical Stimulation, IEEE Transactions on Biomedical Engineering, vol.56, issue.7, pp.1771-1780, 2009. ,
DOI : 10.1109/TBME.2009.2017030
Continuous gait cycle index estimation for electrical stimulation assisted foot drop correction, Journal of NeuroEngineering and Rehabilitation, vol.11, issue.1, pp.118-128, 2014. ,
DOI : 10.1016/j.robot.2007.09.019
URL : https://hal.archives-ouvertes.fr/hal-01060086
Muscle Fatigue: Clinical Implications for Fatigue Assessment and Neuromuscular Electrical Stimulation, Physical Therapy, vol.73, issue.12, pp.902-910, 1993. ,
DOI : 10.1093/ptj/73.12.902
Real-time control of hind limb functional electrical stimulation using feedback from dorsal root ganglia recordings, Journal of Neural Engineering, vol.10, issue.2, pp.26020-26030, 2013. ,
DOI : 10.1088/1741-2560/10/2/026020
Fatigue and non-fatigue mathematical muscle models during functional electrical stimulation of paralyzed muscle, Biomedical Signal Processing and Control, vol.5, issue.2, pp.87-93, 2010. ,
DOI : 10.1016/j.bspc.2009.12.001
Bilateral Upper Limb Training With Functional Electric Stimulation in Patients With Chronic Stroke, Neurorehabilitation and Neural Repair, vol.23, issue.4, pp.357-365, 1177. ,
DOI : 10.1177/1545968308326428
The validity of stimulus-evoked EMG for studying muscle fatigue characteristics of paraplegic subjects during dynamic cycling movement, IEEE Transactions on Rehabilitation Engineering, vol.5, issue.2, pp.170-178, 1997. ,
DOI : 10.1109/86.593288
Surface EMG as a fatigue indicator during FES-induced isometric muscle contractions, Journal of Electromyography and Kinesiology, vol.7, issue.1, pp.27-37, 1997. ,
DOI : 10.1016/S1050-6411(96)00016-8
Common drive of motor units in regulation of muscle force, Trends in Neurosciences, vol.17, issue.7, pp.299-305, 1994. ,
DOI : 10.1016/0166-2236(94)90064-7
Lumbar Root Stimulation for Restoring Leg Function: Stimulator and Measurement of Muscle Actions, Artificial Organs, vol.23, issue.6, 1997. ,
DOI : 10.1111/j.1525-1594.1997.tb04660.x
Chapter 33 Control of standing and gait using electrical stimulation: influence of muscle model complexity on control strategy, Prog. Brain Res, vol.97, issue.08, pp.369-381, 1993. ,
DOI : 10.1016/S0079-6123(08)62296-7
Ambulation After Incomplete Spinal Cord Injury With EMG-Triggered Functional Electrical Stimulation, IEEE Transactions on Biomedical Engineering, vol.55, issue.2, pp.791-794, 2007. ,
DOI : 10.1109/TBME.2007.902225
URL : https://hal.archives-ouvertes.fr/hal-01062440
Human Muscle Function and Fatigue, Ciba Found. Symp, vol.57, pp.1-18, 1981. ,
DOI : 10.1002/9780470715420.ch1
Excitation-contraction fatigue during sustained electrical stimulation of paralyzed muscle, Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, pp.1460-1461, 1996. ,
DOI : 10.1109/IEMBS.1996.647504
Using evoked EMG as a synthetic force sensor of isometric electrically stimulated muscle, IEEE Transactions on Biomedical Engineering, vol.45, issue.2, pp.188-202, 1998. ,
DOI : 10.1109/10.661267
Model-based control of FES-induced single joint movements, IEEE Transactions on Neural Systems and Rehabilitation Engineering, vol.9, issue.3, pp.245-257, 2001. ,
DOI : 10.1109/7333.948452
Newton-method based iterative learning control for robot-assisted rehabilitation using FES, Mechatronics, vol.24, issue.8, pp.934-943, 2014. ,
DOI : 10.1016/j.mechatronics.2014.04.001
Fatigue: Neural and Muscular Mechanisms, 1995. ,
DOI : 10.1007/978-1-4899-1016-5
Selective fatigue of fast motor units after electrically elicited muscle contractions, Journal of Electromyography and Kinesiology, vol.14, issue.5, pp.531-538, 2004. ,
DOI : 10.1016/j.jelekin.2004.03.008
Editorial: Biosignal processing and computational methods to enhance sensory motor neuroprosthetics, Frontiers in Neuroscience, vol.8, issue.181, 2015. ,
DOI : 10.3389/fnins.2014.00181
URL : https://hal.archives-ouvertes.fr/lirmm-01235841
Dual predictive control of electrically stimulated muscle using biofeedback for drop foot correcti, Proceeding in IEEE/RSJ International Conference on Intelligent Robots and Systems, pp.1731-1736, 2011. ,
Evoked EMG-based torque prediction under muscle fatigue in implanted neural stimulation, Journal of Neural Engineering, vol.8, issue.6, pp.6-10, 2011. ,
DOI : 10.1088/1741-2560/8/6/064001
URL : https://hal.archives-ouvertes.fr/lirmm-00630237
Detection of fatigue in the isometric electrical activation of paralyzed hand muscles of persons with tetraplegia, IEEE Transactions on Rehabilitation Engineering, vol.8, issue.3, 2000. ,
DOI : 10.1109/86.867870
Sliding Mode Closed-Loop Control of FES: Controlling the Shank Movement, IEEE Transactions on Biomedical Engineering, vol.51, issue.2, pp.263-272, 2003. ,
DOI : 10.1109/TBME.2003.820393
Implanted functional electrical stimulation: an alternative for standing and walking in pediatric spinal cord injury, Spinal Cord, vol.41, issue.3, pp.144-152, 2003. ,
DOI : 10.1038/sj.sc.3101392
Electrodes for transcutaneous (surface) electrical stimulation, Journal of Automatic Control, vol.18, issue.2, pp.35-45, 2008. ,
DOI : 10.2298/JAC0802035K
URL : http://doi.org/10.2298/jac0802035k
Muscle selection and walking performance of multichannel FES systems for ambulation in paraplegia, IEEE Transactions on Rehabilitation Engineering, vol.5, issue.1, pp.23-29, 1997. ,
DOI : 10.1109/86.559346
EMG and metabolite-based prediction of force in paralyzed quadriceps muscle under interrupted stimulation, IEEE Transactions on Rehabilitation Engineering, vol.7, issue.3, pp.301-314, 1999. ,
DOI : 10.1109/86.788467
Real-time estimation of FES-induced joint torque with evoked EMGapplication to spinal cord injured patients, J. Neuroeng. Rehabil, 2016. ,
A system for realtime estimation of joint torque with evoked EMG under electrical stimulation, Replace, Repair, Restore, Relieve Bridging Clinical and Engineering Solutions in Neurorehabilitation SE -76, 2014. ,
URL : https://hal.archives-ouvertes.fr/lirmm-00983717
Real-time closedloop FES control of muscle activation with evoked EMG feedback, 7th International IEEE/EMBS Conference on Neural Engineering (NER), pp.2015-623, 2015. ,
URL : https://hal.archives-ouvertes.fr/lirmm-01235859
Muscle Fatigue Tracking with Evoked EMG via Recurrent Neural Network: Toward Personalized Neuroprosthetics, IEEE Computational Intelligence Magazine, vol.9, issue.2, pp.38-46, 2014. ,
DOI : 10.1109/MCI.2014.2307224
URL : https://hal.archives-ouvertes.fr/lirmm-00980641
FUNCTIONAL ELECTROTHERAPY, ASAIO Journal, vol.8, issue.1, pp.202-205, 1961. ,
DOI : 10.1097/00002480-196204000-00075
Electrical stimulation for neuromuscular testing and training: state-of-the art and unresolved issues, European Journal of Applied Physiology, vol.28, issue.10, pp.2391-2397, 2011. ,
DOI : 10.1007/s00421-011-2133-7
Transcutaneous functional electrical stimulation for grasping in subjects with cervical spinal cord injury, Spinal Cord, vol.43, issue.1, 2005. ,
DOI : 10.1038/sj.sc.3101644
Electrically evoked myoelectric signals, Crit. Rev. Biomed. Eng, vol.19, pp.293-340, 1992. ,
DOI : 10.1109/iembs.1992.5761830
EMG as an indicator of fatigue in isometrically FES-activated paralyzed muscles, IEEE Transactions on Rehabilitation Engineering, vol.2, issue.2, pp.57-65, 1994. ,
DOI : 10.1109/86.313147
Predicted and Measured Muscle Forces after Recoveries of Differing Durations Following Fatigue in Functional Electrical Stimulation, Artificial Organs, vol.333, issue.3, pp.236-239, 1997. ,
DOI : 10.1111/j.1525-1594.1997.tb04657.x
Neural Interface Devices: Spinal Cord Stimulation Technology, Proc. IEEE 96, pp.1108-1119, 2008. ,
DOI : 10.1109/JPROC.2008.922558
The development of a potential optimized stimulation intensity envelope for drop foot applications, IEEE Transactions on Neural Systems and Rehabilitation Engineering, vol.11, issue.3, pp.249-256817678, 2003. ,
DOI : 10.1109/TNSRE.2003.817678
Muscle fatigue characteristics in paralyzed muscle after spinal cord injury, Spinal Cord, vol.87, issue.1, 2011. ,
DOI : 10.1007/BF00417776
Model-based development of neuroprosthesis for paraplegic patients, Philos. Trans. R. Soc. Lond. Series B Biol. Sci, vol.354, pp.877-894, 1999. ,
Biomechanical model of the human knee evaluated by neuromuscular stimulation, Journal of Biomechanics, vol.29, issue.9, pp.1157-1167, 1996. ,
DOI : 10.1016/0021-9290(96)00012-7
Wireless Distributed Architecture for Therapeutic Functional Electrical Stimulation: a technology to design network-based muscle control, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology, pp.6218-6221, 2010. ,
DOI : 10.1109/IEMBS.2010.5627724
URL : https://hal.archives-ouvertes.fr/lirmm-00506293
Implanted functional neuromuscular stimulation systems for individuals with cervical spinal cord injuries: Clinical case reports, Archives of Physical Medicine and Rehabilitation, vol.77, issue.11, pp.1119-1128, 1996. ,
DOI : 10.1016/S0003-9993(96)90133-1
An Approach to Applying Feedback Error Learning for Functional Electrical Stimulation Controller: Computer Simulation Tests of Wrist Joint Control, Advances in Artificial Neural Systems, vol.32, issue.10, pp.1-8, 2010. ,
DOI : 10.1016/0021-9290(96)00026-7
Evoked Electromyography-Based Closed-Loop Torque Control in Functional Electrical Stimulation, IEEE Transactions on Biomedical Engineering, vol.60, issue.8, pp.2299-2307, 2013. ,
DOI : 10.1109/TBME.2013.2253777
URL : https://hal.archives-ouvertes.fr/lirmm-00806283
FES-Induced Torque Prediction With Evoked EMG Sensing for Muscle Fatigue Tracking, IEEE/ASME Transactions on Mechatronics, vol.16, issue.5, pp.816-826, 2011. ,
DOI : 10.1109/TMECH.2011.2160809
URL : https://hal.archives-ouvertes.fr/lirmm-00604670
Muscle fatigue tracking based on stimulus evoked EMG and adaptive torque prediction, 2011 IEEE International Conference on Robotics and Automation, pp.1433-1438, 2011. ,
DOI : 10.1109/ICRA.2011.5980087
URL : https://hal.archives-ouvertes.fr/lirmm-00588948
Comparison of regression models for estimation of isometric wrist joint torques using surface electromyography, Journal of NeuroEngineering and Rehabilitation, vol.8, issue.1, pp.56-66, 2011. ,
DOI : 10.1109/TRA.2003.808873