C. Nguan, B. Miller, R. Patel, P. P. Luke, and C. M. Schlachta, Pre-clinical remote telesurgery trial of a da Vinci telesurgery prototype, The International Journal of Medical Robotics and Computer Assisted Surgery, vol.1, issue.4, pp.304-309, 2008.
DOI : 10.1002/rcs.99

L. Panait, E. Akkary, R. L. Bell, K. E. Roberts, S. J. Dudrick et al., The Role of Haptic Feedback in Laparoscopic Simulation Training, Journal of Surgical Research, vol.156, issue.2, pp.312-316, 2009.
DOI : 10.1016/j.jss.2009.04.018

A. M. Tahmasebi, K. Hashtrudi-zaad, D. Thompson, and P. Abolmaesumi, A Framework for the Design of a Novel Haptic-Based Medical Training Simulator, IEEE Transactions on Information Technology in Biomedicine, vol.12, issue.5, pp.658-666, 2008.
DOI : 10.1109/TITB.2008.926496

J. Artigas and G. Hirzinger, A brief history of dlr's space telerobotics and force-feedback teleoperation, Acta Polytech. Hung, vol.13, issue.1, pp.239-249, 2016.

N. Marturi, A. Rastegarpanah, C. Takahashi, M. Adjigble, R. Stolkin et al., Towards advanced robotic manipulation for nuclear decommissioning: A pilot study on tele-operation and autonomy, 2016 International Conference on Robotics and Automation for Humanitarian Applications (RAHA), pp.1-8, 2016.
DOI : 10.1109/RAHA.2016.7931866

R. R. Murphy, K. L. Dreger, S. Newsome, J. Rodocker, E. Steimle et al., Use of remotely operated marine vehicles at Minamisanriku and Rikuzentakata Japan for disaster recovery, 2011 IEEE International Symposium on Safety, Security, and Rescue Robotics, pp.19-25, 2011.
DOI : 10.1109/SSRR.2011.6106798

P. F. Hokayem and M. W. Spong, Bilateral teleoperation: An historical survey, Automatica, vol.42, issue.12, pp.2035-2057, 2006.
DOI : 10.1016/j.automatica.2006.06.027

Z. Li, Y. Xia, and F. Sun, Adaptive Fuzzy Control for Multilateral Cooperative Teleoperation of Multiple Robotic Manipulators Under Random Network-Induced Delays, IEEE Transactions on Fuzzy Systems, vol.22, issue.2, pp.437-450, 2014.
DOI : 10.1109/TFUZZ.2013.2260550

Z. Li, Y. Xia, D. Wang, D. Zhai, C. Y. Su et al., Neural Network-Based Control of Networked Trilateral Teleoperation With Geometrically Unknown Constraints, IEEE Transactions on Cybernetics, vol.46, issue.5, pp.1051-1064, 2016.
DOI : 10.1109/TCYB.2015.2422785

C. Bergeles and G. Yang, From Passive Tool Holders to Microsurgeons: Safer, Smaller, Smarter Surgical Robots, IEEE Transactions on Biomedical Engineering, vol.61, issue.5, pp.1565-1576, 2014.
DOI : 10.1109/TBME.2013.2293815

V. Vitiello, S. Lee, T. P. Cundy, and G. Yang, Emerging Robotic Platforms for Minimally Invasive Surgery, IEEE Reviews in Biomedical Engineering, vol.6, pp.111-126, 2013.
DOI : 10.1109/RBME.2012.2236311

R. H. Taylor, A. Menciassi, G. Fichtinger, P. Fiorini, and P. Dario, Medical robotics and computer-integrated surgery, pp.1657-1684, 2016.

C. S. Karas and E. A. Chiocca, Neurosurgical robotics: a review of brain and spine applications, Journal of Robotic Surgery, vol.47, issue.1???4, pp.39-43, 2007.
DOI : 10.1007/978-3-7091-6687-1_14

J. Burgner, D. C. Rucker, H. B. Gilbert, P. J. Swaney, P. T. Russell et al., A Telerobotic System for Transnasal Surgery, IEEE/ASME Transactions on Mechatronics, vol.19, issue.3, pp.996-1006, 2014.
DOI : 10.1109/TMECH.2013.2265804

, Author's personal copy, J Intell Robot Syst

F. W. Mohr, V. Falk, A. Diegeler, T. Walther, J. F. Gummert et al., Computer-enhanced ???robotic??? cardiac surgery: Experience in 148 patients, The Journal of Thoracic and Cardiovascular Surgery, vol.121, issue.5, pp.842-853, 2001.
DOI : 10.1067/mtc.2001.112625

A. M. Okamura, Methods for haptic feedback in teleoperated robot???assisted surgery, Industrial Robot: An International Journal, vol.31, issue.6, pp.499-508, 2004.
DOI : 10.1109/87.491198

M. Tavakoli, Haptics for teleoperated surgical robotic systems, 2008.
DOI : 10.1142/6816

R. Christopher, S. Nicholas, and D. Robert, The role of force feedback in surgery: analysis of blunt dissection, 10Th Symposium on Haptic Interface for Virtual Environment and Teleoperator Systems, pp.18-125, 2002.

L. Meli, C. Pacchierotti, and D. Prattichizzo, Sensory Subtraction in Robot-Assisted Surgery: Fingertip Skin Deformation Feedback to Ensure Safety and Improve Transparency in Bimanual Haptic Interaction, IEEE Transactions on Biomedical Engineering, vol.61, issue.4, pp.1318-1327, 2014.
DOI : 10.1109/TBME.2014.2303052

A. Konstantinova, J. Jiang, A. Althoefer, K. Dasgupta, P. Nanayakkara et al., Comprehensive guide to steam sterilization and sterility assurance in health care facilities Association for the Advancement of Medical Instrumentation Arlington, VA 21 Implementation of tactile sensing for palpation in robot-assisted minimally invasive surgery: a review, A1:2010, pp.2490-2501, 2011.

P. Hinterseer, S. Hirche, S. Chaudhuri, E. Steinbach, and M. Buss, Perception-Based Data Reduction and Transmission of Haptic Data in Telepresence and Teleaction Systems, IEEE Transactions on Signal Processing, vol.56, issue.2, pp.588-597, 2008.
DOI : 10.1109/TSP.2007.906746

M. Kuschel, P. Kremer, and M. Buss, Passive Haptic Data-Compression Methods With Perceptual Coding for Bilateral Presence Systems, IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans, vol.39, issue.6, pp.1142-1151, 2009.
DOI : 10.1109/TSMCA.2009.2027219

G. Kokkonis, K. Psannis, M. S. Roumeliotis, and S. Kontogiannis, A Survey of Transport Protocols for Haptic Applications, 2012 16th Panhellenic Conference on Informatics, pp.192-197, 2012.
DOI : 10.1109/PCi.2012.54

G. Tortora, P. Dario, and A. Menciassi, Array of Robots Augmenting the Kinematics of Endocavitary Surgery, IEEE/ASME Transactions on Mechatronics, vol.19, issue.6, pp.1821-1829, 2014.
DOI : 10.1109/TMECH.2013.2296531

J. Guo, C. Liu, and P. Poignet, Scaled position-force tracking for wireless teleoperation of miniaturized surgical robotic system, 2014 36th Annual International Conference of the IEEE, pp.361-365, 2014.
URL : https://hal.archives-ouvertes.fr/lirmm-01275470

T. S. Shine, Specialized Operating Room (Chapter 13, Operation Room Design Manual, pp.44-56, 2012.

R. J. Anderson and M. W. Spong, Bilateral control of teleoperators with time delay, IEEE Transactions on Automatic Control, vol.34, issue.5, pp.494-501, 1989.
DOI : 10.1109/9.24201

G. Niemeyer and J. Slotine, Stable adaptive teleoperation, IEEE Journal of Oceanic Engineering, vol.16, issue.1, pp.152-162, 1991.
DOI : 10.1109/48.64895

H. Baier and G. Schmidt, Transparency and Stability of Bilateral Kinesthetic Teleoperation with Time-Delayed Communication, Journal of Intelligent and Robotic Systems, vol.40, issue.1, pp.1-22, 2004.
DOI : 10.1023/B:JINT.0000034338.53641.d0

E. Nuño, L. Basañez, and R. Ortega, Passivity-based control for bilateral teleoperation: A tutorial, Automatica, vol.47, issue.3, pp.485-495, 2011.
DOI : 10.1016/j.automatica.2011.01.004

Q. Deng, Q. Wei, and Z. Li, Analysis of absolute stability for time-delay teleoperation systems, International Journal of Automation and Computing, vol.27, issue.5, pp.203-207, 2007.
DOI : 10.1109/ROBOT.1997.614372

M. Franken, S. Stramigioli, S. Misra, C. Secchi, and A. Macchelli, Bilateral Telemanipulation With Time Delays: A Two-Layer Approach Combining Passivity and Transparency, IEEE Transactions on Robotics, vol.27, issue.4, pp.741-756, 2011.
DOI : 10.1109/TRO.2011.2142430

C. Yang, X. Wang, Z. Li, Y. Li, and C. Su, Teleoperation Control Based on Combination of Wave Variable and Neural Networks, IEEE Transactions on Systems, Man, and Cybernetics: Systems, vol.47, issue.8, pp.47-2125, 2017.
DOI : 10.1109/TSMC.2016.2615061

K. Kawashima, K. Tadano, C. Wang, G. Sankaranarayanan, and B. Hannaford, Bilateral teleoperation with time delay using modified wave variable based controller, ICRA'09 IEEE International Conference on Robotics and Automation, pp.4326-4331, 2009.

L. Bate, C. D. Cook, and Z. Li, Reducing Wave-Based Teleoperator Reflections for Unknown Environments, IEEE Transactions on Industrial Electronics, vol.58, issue.2, pp.392-397, 2011.
DOI : 10.1109/TIE.2009.2035994

Y. Ye and P. X. Liu, Improving haptic feedback fidelity in wavevariable-based teleoperation orientated to telemedical applications, IEEE Trans. Instrum. Meas, vol.58, issue.8, pp.2847-2855, 2009.

Y. Ye and P. X. Liu, Improving trajectory tracking in wave-variablebased teleoperation, IEEE/ASME Trans. Mechatron, vol.15, issue.2, pp.321-326, 2010.

H. Li and K. Kawashima, Achieving stable tracking in wavevariable-based teleoperation, IEEE/ASME Trans. Mechatron, vol.19, issue.5, pp.1574-1582, 2014.

J. Zhu, X. He, and W. Gueaieb, Trends in the control schemes for bilateral teleoperation with time delay Autonomous and Intelligent Systems, Lecture Notes in Computer Science, vol.6752, 2011.

R. Muradore and P. Fiorini, A review of bilateral teleoperation algorithms, Acta Polytechnica Hungarica, vol.13, issue.1, pp.191-208, 2016.

A. A. Ghavifekr, A. R. Ghiasi, and M. A. Badamchizadeh, SUMMARY, Robotica, vol.39, issue.04, pp.552-569, 2018.
DOI : 10.1177/02783640122067471

J. Guo, C. Liu, and P. Poignet, Stable and enhanced position-force tracking for bilateral teleoperation with time delay, 2015 European Control Conference (ECC), pp.1980-1985, 2015.
DOI : 10.1109/ECC.2015.7330829

URL : https://hal.archives-ouvertes.fr/lirmm-01275452

D. A. Lawrence, Stability and transparency in bilateral teleoperation, IEEE Transactions on Robotics and Automation, vol.9, issue.5, pp.624-637, 1993.
DOI : 10.1109/70.258054

S. Munir and W. J. Book, Wave-based teleoperation with prediction, Proceedings of the 2001 American Control Conference. (Cat. No.01CH37148), pp.4605-4611, 2001.
DOI : 10.1109/ACC.2001.945706

G. D. Niemeyer, Using wave variables in time delayed force reflecting teleoperation, 1996.

H. Ching and W. J. Book, Internet-Based Bilateral Teleoperation Based on Wave Variable With Adaptive Predictor and Direct Drift Control, Journal of Dynamic Systems, Measurement, and Control, vol.8, issue.1, pp.86-93, 2006.
DOI : 10.1109/48.64895

P. Moreira, N. Zemiti, C. Liu, and P. Poignet, Viscoelastic model based force control for soft tissue interaction and its application in physiological motion compensation, Computer Methods and Programs in Biomedicine, vol.116, issue.2, pp.52-67, 2014.
DOI : 10.1016/j.cmpb.2014.01.017

URL : https://hal.archives-ouvertes.fr/lirmm-00940940

L. A. Sanchez, M. Le, C. Liu, N. Zemiti, and P. Poignet, The impact of interaction model on stability and transparency in bilateral teleoperation for medical applications, 2012 IEEE International Conference on Robotics and Automation, pp.1607-1613, 2012.
DOI : 10.1109/ICRA.2012.6225314

URL : https://hal.archives-ouvertes.fr/lirmm-00808388

K. Hashtrudi-zaad and S. E. Salcudean, Analysis of Control Architectures for Teleoperation Systems with Impedance/Admittance Master and Slave Manipulators, The International Journal of Robotics Research, vol.20, issue.6, pp.419-445, 2001.
DOI : 10.1109/70.326566

S. W. Downing, W. A. Herzog, J. S. Mclaughlin, and T. P. Gilbert, Beating-heart mitral valve surgery: Preliminary model and methodology, The Journal of Thoracic and Cardiovascular Surgery, vol.123, issue.6, pp.1141-1146, 2002.
DOI : 10.1067/mtc.2002.121680

M. Mitsuishi, Medical Robot and Master Slave System for Minimally Invasive Surgery, 2007 IEEE/ICME International Conference on Complex Medical Engineering, pp.8-13, 2007.
DOI : 10.1109/ICCME.2007.4381682

V. Puvanesarajah, J. A. Liauw, S. Lo, I. A. Lina, and T. F. Witham, Techniques and accuracy of thoracolumbar pedicle screw placement, World Journal of Orthopedics, vol.5, issue.2, p.112, 2014.
DOI : 10.1007/s00586-009-1065-y

M. Tavakoli, R. V. Patel, and M. Moallem, Bilateral control of a teleoperator for soft tissue palpation: design and experiments, Proceedings 2006 IEEE International Conference on Robotics and Automation, 2006. ICRA 2006., pp.3280-3285, 2006.
DOI : 10.1109/ROBOT.2006.1642202

G. A. Christiansson and F. C. Van-der-helm, The Low-Stiffness Teleoperator Slave ??? a Trade-off between Stability and Performance, The International Journal of Robotics Research, vol.26, issue.3, pp.287-299, 2007.
DOI : 10.1109/70.258054

N. Colonnese and A. M. Okamura, Analysis of effective impedance transmitted to the operator in position-exchange bilateral teleoperation, 2017 IEEE World Haptics Conference (WHC), pp.328-333, 2017.
DOI : 10.1109/WHC.2017.7989923

P. Moreira, S. Patil, R. Alterovitz, and S. Misra, Needle steering in biological tissue using ultrasound-based online curvature estimation, 2014 IEEE International Conference on Robotics and Automation (ICRA), pp.4368-4373, 2014.
DOI : 10.1109/ICRA.2014.6907495

URL : http://europepmc.org/articles/pmc4517621?pdf=render

B. Jian, W. Gao, D. Kacher, E. Nevo, B. Fetics et al., Kalman filter-based EM-optical sensor fusion for needle deflection estimation, International Journal of Computer Assisted Radiology and Surgery, vol.373, issue.1, pp.573-583, 2018.
DOI : 10.1056/NEJMc1415448