Comparative analysis of transverse intrafascicular multichannel, longitudinal intrafascicular and multipolar cuff electrodes for the selective stimulation of nerve fascicles, Journal of neural engineering, vol.8, issue.3, p.21558601, 2011. ,
Multielectrode intrafascicular and extraneural stimulation, Medical and Biological Engineering and Computing, vol.27, issue.1, p.2779293, 1989. ,
Selective stimulation of peripheral nerve fibers using dual intrafascicular electrodes, IEEE transactions on biomedical engineering, vol.40, issue.5, p.8225338, 1993. ,
A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve, Biosensors and Bioelectronics, vol.26, issue.1, p.20627510, 2010. ,
Functionally selective peripheral nerve stimulation with a flat interface nerve electrode, IEEE Transactions on Neural Systems and Rehabilitation Engineering, vol.10, issue.4, p.12611367, 2002. ,
A nerve cuff technique for selective excitation of peripheral nerve trunk regions, IEEE Transactions on Biomedical Engineering, vol.37, issue.7, p.2394459, 1990. ,
Transverse tripolar stimulation of peripheral nerve: a modelling study of spatial selectivity, Medical & Biological Engineering & Computing, vol.36, issue.1, pp.66-74, 1998. ,
Selectivity of multiple-contact nerve cuff electrodes: a simulation analysis, IEEE Transactions on Biomedical Engineering, vol.48, issue.2, p.11296872, 2001. ,
Model based optimal multipolar stimulation without a priori knowledge of nerve structure: application to vagus nerve stimulation, Journal of neural engineering, vol.15, issue.4, p.29664415, 2018. ,
URL : https://hal.archives-ouvertes.fr/lirmm-01770039
Selective control of muscle activation with a multipolar nerve cuff electrode, IEEE transactions on bio-medical engineering, vol.40, issue.7, p.8244425, 1993. ,
Transverse versus longitudinal tripolar configuration for selective stimulation with multipolar cuff electrodes, IEEE transactions on bio-medical engineering, vol.58, issue.4, p.21421427, 2011. ,
A Distributed Architecture for Activating the Peripheral Nervous System, Journal of Neural Engineering, vol.6, pp.1-018, 2009. ,
URL : https://hal.archives-ouvertes.fr/lirmm-00361686
Delaying discharge after the stimulus significantly decreases muscle activation thresholds with small impact on the selectivity: an in vivo study using TIME, Medical & biological engineering & computing, vol.53, issue.4, pp.371-379, 2015. ,
URL : https://hal.archives-ouvertes.fr/lirmm-01116454