J. A. Sandretto, D. Daney, and M. Gouttefarde, Calibration of a fullyconstrained parallel cable-driven robot, 19th CISM-IFToMM Symposium on Robot Design, Dynamics, and Control, 2012.
URL : https://hal.archives-ouvertes.fr/hal-00668921

A. Fortin-côté, P. Cardou, and C. Gosselin, An admittance control scheme for haptic interfaces based on cable-driven parallel mechanisms, Proceedings -IEEE International Conference on Robotics and Automation, pp.819-825, 2014.

S. Garrido-jurado, R. Muñoz-salinas, F. J. Madrid-cuevas, and R. Medinacarnicer, Generation of fiducial marker dictionaries using Mixed Integer Linear Programming, Pattern Recognition, vol.51, pp.481-491, 2016.

J. Izard, M. Gouttefarde, M. Michelin, O. Tempier, and C. Baradat, A Reconfigurable Robot for Cable-Driven Parallel Robotic Research and Industrial Scenario Proofing, Cable-Driven Parallel Robots, pp.135-148, 2013.

W. Khalil and S. Besnard, Self calibration of Stewart-Gough parallel robots without extra sensors, IEEE Transactions on Robotics and Automation, vol.15, issue.6, pp.1116-1121, 1999.

D. Lau, Initial Length and Pose Calibration for Cable-Driven Parallel Robots with Relative Length Feedback, Cable-Driven Parallel Robots, pp.140-151, 2018.

R. K. Lenz and R. Y. Tsai, Calibrating a Cartesian robot with eye-on-hand configuration independent of eye-to-hand relationship, IEEE Transactions on Pattern Analysis and Machine Intelligence, vol.11, issue.9, pp.916-928, 1989.

J. Mattingley and S. Boyd, CVXGEN: A code generator for embedded convex optimization, Optimization and Engineering, vol.13, issue.1, pp.1-27, 2012.

R. Meziane, P. Cardou, and M. J. Otis, Cable interference control in physical interaction for cable-driven parallel mechanisms. Mechanism and Machine Theory, vol.132, pp.30-47, 2019.

P. Miermeister and A. Pott, Auto Calibration Method for Cable-Driven Parallel Robots Using Force Sensors, Latest Advances in Robot Kinematics, pp.269-276, 2012.

R. Muñoz-salinas, M. J. Marín-jimenez, E. Yeguas-bolivar, and R. Medinacarnicer, Mapping and localization from planar markers, Pattern Recognition, vol.73, pp.158-171, 2018.

A. J. Patel and K. F. Ehmann, Calibration of a hexapod machine tool using a redundant leg, International Journal of Machine Tools and Manufacture, vol.40, issue.4, pp.489-512, 2000.

P. Renaud, N. Andreff, F. Marquet, and P. Martinet, Vision-based kinematic calibration of a H4 parallel mechanism, IEEE International Conference on Robotics and Automation (Cat. No.03CH37422), vol.1, pp.1191-1196, 2003.

F. J. Romero-ramirez, R. Muñoz-salinas, and R. Medina-carnicer, Speeded up detection of squared fiducial markers, Image and Vision Computing, vol.76, pp.38-47, 2018.

H. Zhuang, O. Masory, and J. Yan, Kinematic calibration of a Stewart platform using pose measurements obtained by a single theodolite. Intelligent Robots and Systems 95, Proceedings. 1995 IEEE/RSJ International Conference on, vol.2, pp.329-334, 1995.

H. Zhuang, J. Yan, and O. Masory, Calibration of Stewart platforms and other parallel manipulators by minimizing inverse kinematic residuals, Journal of Robotic Systems, vol.15, pp.395-405, 1998.