Toward Accurate Volumetry of Brain Aneurysms: Combination of an Algorithm for Automatic Thresholding with a 3D Eraser Tool

Vincent Costalat 1 Igor Lima Maldonado 1, * Olivier Strauss 2 Alain Bonafé 1
* Auteur correspondant
2 ICAR - Image & Interaction
LIRMM - Laboratoire d'Informatique de Robotique et de Microélectronique de Montpellier
Abstract : The present study describes a new approach for aneurysm volume quantification on three-dimensional angiograms, which focuses on solving three common technical problems: the variability associated with the use of manual thresholds, the irregular morphology of some aneurysms, and the imprecision of the limits between the parent artery and the aneurysm sac. The method consists of combining an algorithm for automatic threshold determination with a spherical eraser tool that allows the user to separate the image of the aneurysm from the parent artery. The accuracy of volumetry after automatic thresholding was verified with an in vitro experiment in which 57 measurements were performed using four artificial aneurysms of known volume. The reliability of the method was compared to that obtained with the technique of ellipsoid approximation in a clinical setting of 15 real angiograms and 150 measurements performed by five different users. The mean error in the measurement of the artificial aneurysms was 7.23%. The reliability of the new approach was significantly higher than that of the ellipsoid approximation. Limits of agreement between two measurements were determined with Bland-Altman plots and ranged from −14 to 13% for complex and from −10.8 to 11.03% for simple-shaped sacs. The reproducibility was lower (>20% of variation) for small aneurysms (<70 mm3) and for those presenting a very wide neck (dome-to-neck ratio < 1). The method is potentially useful in the clinical practice, since it provides relatively precise, reproducible, volume quantification. A safety coiling volume can be established in order to perform sufficient but not excessive filling of the aneurysm pouch.
Type de document :
Article dans une revue
Journal of Neuroscience Methods, Elsevier, 2011, OnLine, pp.7. 〈10.1016/j.jneumeth.2011.04.008〉
Liste complète des métadonnées

Littérature citée [21 références]  Voir  Masquer  Télécharger

https://hal-lirmm.ccsd.cnrs.fr/lirmm-00595241
Contributeur : Olivier Strauss <>
Soumis le : mardi 24 mai 2011 - 11:22:30
Dernière modification le : mardi 16 octobre 2018 - 07:52:01

Fichier

CostalatMaldonadoStraussBonaff...
Fichiers éditeurs autorisés sur une archive ouverte

Identifiants

Collections

Citation

Vincent Costalat, Igor Lima Maldonado, Olivier Strauss, Alain Bonafé. Toward Accurate Volumetry of Brain Aneurysms: Combination of an Algorithm for Automatic Thresholding with a 3D Eraser Tool. Journal of Neuroscience Methods, Elsevier, 2011, OnLine, pp.7. 〈10.1016/j.jneumeth.2011.04.008〉. 〈lirmm-00595241〉

Partager

Métriques

Consultations de la notice

370

Téléchargements de fichiers

184