Frequency domain power and thermal integrity analysis of 3D power delivery networks - LIRMM - Laboratoire d’Informatique, de Robotique et de Microélectronique de Montpellier
Conference Papers Year : 2013

Frequency domain power and thermal integrity analysis of 3D power delivery networks

Aida Todri-Sanial

Abstract

3D power delivery networks are essential for delivering supply voltage to all tiers. PDNs on each tier are mesh networks that are bridged together using Through-Silicon-Vias (TSVs) to devise 3D PDNs. However, a host of vulnerabilities influence their resiliency and reliability such as power supply noise, long parasitic current paths, switching activities, high frequencies, and sensitivity to temperature variations. In this work, we perform a qualitative analysis to capture the impact of TSV-to-TSV substrate coupling (inductive and capacitive), power supply noise transfer among tiers, and different PDN topologies on 3D PDNs. Experiments show the criticality of these factors and their impact on power and thermal integrity of 3D PDNs.
No file

Dates and versions

lirmm-01973645 , version 1 (08-01-2019)

Identifiers

Cite

Aida Todri-Sanial. Frequency domain power and thermal integrity analysis of 3D power delivery networks. SPI: Signal and Power Integrity, May 2013, Paris, France. ⟨10.1109/SaPIW.2013.6558328⟩. ⟨lirmm-01973645⟩
141 View
0 Download

Altmetric

Share

More