Design and Implementation of a Flexible Interface for TID Detector

Abstract

This paper introduces a flexible sensor interface for a radiation Total Ionizing Dose (TID) monitor. The board is conceived to be flexible and could be used with several detectors, the results reported in this work are based on the radiation-induced shift of the threshold voltage of a FET transistor that is polarized by current The system has been tested for a range of radiation in Co60 facility up to about 5 krad, which corresponds to the double of the TID that will face the Cubesat MTCUBE for a two-year nominal mission in a low orbit.
Fichier principal
Vignette du fichier
2019_IWASI____Design_and_Implementation_of_a_Flexible_Interface_for_TID_Detector___HAL_Version.pdf (1.51 Mo) Télécharger le fichier
Origin Files produced by the author(s)

Dates and versions

lirmm-02415559 , version 1 (29-09-2021)

Identifiers

Cite

Iacopo Fara, Lucas Matana Luza, Jérôme Boch, Gianluca Furano, Marco Ottavi, et al.. Design and Implementation of a Flexible Interface for TID Detector. IWASI 2019 - 8th IEEE International Workshop on Advances in Sensors and Interfaces, Jun 2019, Otranto, Italy. pp.158-162, ⟨10.1109/IWASI.2019.8791299⟩. ⟨lirmm-02415559⟩